Your cart is empty.
Your cart is empty. How to set parameters?
1. First determine the working mode of the relay.
2. According to the working mode of the relay, in the main interface (when the module is powered on, the current working mode (default P1.1 mode) will flash, and then enter the main interface,) "Press and hold the SET button for 2 seconds and then release "Enter the mode selection interface, short press the UP and DOWN keys to select the mode to be set (P1.1~P-4);
3. After selecting the mode that needs to be set (such as P3.2), short press the SET key to set the corresponding parameters. The parameters to be set at this time will flash (OP opening time, CL closing time, LOP cycle number ("-- -" represents infinite loop)). Adjust the parameter value through UP and DOWN, and support long press (rapid increase or decrease) and Short press (increase or decrease by 1 unit): After setting the parameter value, short press the STOP key to select the decimal point position and select the timing range (corresponding time from 0.1 seconds to 999 minutes); short press the SET key to set the next parameter of the current mode , the process is the same as above;
4. After setting the parameters for the selected mode, press and hold the SET button for 2 seconds and release. The currently set mode will flash and then return to the main interface. Parameters are set successfully.